Detection Technology
Select Cable Test Equipment by Voltage Level
In the handover test and preventive test of power cables, the selection of voltage level for testing equipment is directly related to the effectiveness of test results and the safety of equipment operation. Cables of different voltage levels have vastly different requirements for test voltage, equipment capacity, and measurement accuracy. Improper selection may not only lead to distortion of test data, but may also cause equipment damage or personnel safety accidents.
The basic logic of selection: using voltage level as the anchor point
According to relevant standards, the selection of cable testing equipment should comprehensively consider the rated voltage, capacitance, laying length, and on-site working conditions of the tested cable. The technical team of Wuhan UHV Power Technology Co., Ltd. (hereinafter referred to as "Wuhan UHV") has summarized a core principle in practice: the rated output voltage of the test equipment should be higher than the maximum test voltage specified in the standard, and a margin of 1.1 to 1.25 times should be retained to cope with output fluctuations caused by on-site capacitance changes and frequency deviations.
Medium and low voltage cables: very-low frequency equipment has more on-site advantages
For 10kV and 35kV distribution cables, the AC withstand voltage test voltage is usually 22kV and 52kV, respectively. These cables have a large capacitance, and using traditional power frequency test transformers not only makes the equipment bulky, but also makes it difficult to meet the large capacity requirements of on-site power supply conditions. The VLF high voltage generator launched by Wuhan UHV adopts a 0.1Hz sine wave or cosine square wave output, and the equipment capacity can be reduced to 1/500 of the power frequency. The controller is only 4kg and the booster is 25kg, which is particularly suitable for preventive testing and handover testing of distribution network cables. Its output frequency supports three options: 0.1Hz, 0.05Hz, and 0.02Hz. The 0.1Hz range has a load capacity of 1.1 μ F, which can cover the testing needs of most medium and low voltage cables.
High voltage cable: series resonant device is the mainstream solution
The test voltage for cables with voltage levels of 110kV and above usually reaches 128kV or above, which puts higher requirements on equipment capacity and insulation level. The UHV series series series series resonance test device of Wuhan UHV can form a resonance state at a specific frequency by adjusting the relationship between the inductance of the reactor and the capacitance of the tested cable. Only a small amount of energy is needed to maintain the oscillation and output high voltage, greatly reducing the power capacity requirement. This device is suitable for 30-300Hz frequency conversion resonance mode. Power cables usually operate at a frequency of around 35Hz, and the rated voltage of the equipped capacitive voltage divider must be higher than the actual test voltage to ensure the stability and accuracy of high-voltage measurement.
The Effect of Equipment Selection Actual Engineering Perspective
Wuhan UHV used UHV series series series resonant devices in a 110kV, 8-kilometer long cable withstand voltage test project in Hangzhou. The after-sales technical team participated in the entire test operation, and all indicators ultimately met the national standard requirements. In addition, the company's independently developed new generation high-voltage testing system has been exported to well-known cable manufacturing factories in South Korea. The equipment can stably output 70kV high voltage and is equipped with intelligent functions such as automatic tuning, overvoltage protection, real-time data acquisition, and remote monitoring, strictly complying with domestic and foreign standards such as IEC 60270 and GB/T 3048.
Selection also needs to pay attention to measurement accuracy and on-site adaptability
Wuhan UHV technicians remind users that when purchasing equipment, they should not only focus on "how much voltage can be output", but also pay attention to the measurement range and system measurement accuracy of the capacitive voltage divider. At present, the measurement accuracy of mainstream high-quality series resonance test devices can generally reach level 1.5 or even higher, with a frequency resolution of 0.1Hz, which can automatically track the resonance point and ensure stable output voltage. For large cables or GIS equipment, capacity calculation should also be combined with the capacitance of the test sample and the test current to ensure that the equipment's carrying capacity meets the requirements under actual operating conditions.
Wuhan UHV Power Technology Co., Ltd. is rooted in Wuhan · China Optics Valley. After 22 years of technological accumulation, its products have covered multiple categories such as series resonance test devices, ultra-low frequency high-voltage generators, partial discharge testing systems, etc., and are exported to more than 100 countries and regions around the world. In the field of cable testing equipment selection, the company can provide a full chain solution equipment configuration to on-site technical support for application scenarios of different voltage levels.